en:dpi:dpi_components:mediaserver:cache_trouble_shooting:cache_trouble_diagnostic_on [2018/05/07 12:20] – created kvazikraven:dpi:dpi_components:mediaserver:cache_trouble_shooting:cache_trouble_diagnostic_on [2023/08/30 08:44] (current) – removed elena.krasnobryzh
Line 1: Line 1:
-====== 8 ====== 
-{{indexmenu_n>8}} 
-1.To find out the PID of the main process: 
-  ps -ef | grep ccu 
-   
-2. Run the command 
-  ccu manage --conf /etc/ccu/ccu.conf --pid <PID of the main process> --set-log-level diagnostic 
  
-3. Wait 20 minutes\\ 
-4. Run the command 
-  ccu manage --conf /etc/ccu/ccu.conf --pid <PID of the main process> --set-log-level info 
- 
-Commands from 2 and 4 items change the logging level, if it is set to diagnostic, then none of the above should be done, just examine the log /var/log/ccu/online.log\\ 
- 
-The /var/log/ccu/online.log file contains the informaion have been accumulated in different caches yet\\ 
- 
-Also, you can examine the log /var/log/ccu/online_recv.log file - if it is empty, then nothing comes from IPFIX \\