QoE Stor Configuration [Документация VAS Experts]

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
en:dpi:dpi_components:dpiui:user_guide:admin_section:qoestor_man:configuration_qoe_stor:start [2023/08/29 07:43] edrudichgmailcomen:dpi:dpi_components:dpiui:user_guide:admin_section:qoestor_man:configuration_qoe_stor:start [Unknown date] (current) – removed - external edit (Unknown date) 127.0.0.1
Line 1: Line 1:
-====== QoE Stor Configuration ====== 
-{{indexmenu_n>1}} 
- 
- 
-To go to the section, click the ADMINISTRATOR menu item, then click the QOE STOR CONFIGURATION menu item. 
- 
-{{ en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration:pth_1.png? 800 }} 
- 
-===== QoE Stor Nodes ===== 
-This subsection contains the user's servers. To create or view a custom server that provides access to work in the "QoE Stor Configuration", you need to go to __[[en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:start|«Equipment»]]__ 
- 
-===== Configuration ===== 
-This subsection contains the following settings: 
- 
-==== 1 Receivers ==== 
- 
-To add it, click on the **"Add receiver"** button, fill in the following parameters in the window that opens: 
- 
-{{ en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration:create_2.png? 500 }} 
- 
-  * **The receiver type** is selected from the drop-down list. 
-  * **Rotation in minutes** is specified manually by the user. Implies the period of the receiver dump or the period of data loading into the databas. 
- 
-__//By default//__: receiver type – Netflow, rotation – 10 min; 
-receiver type – Clickstream, rotation - 12 min.\\ 
-__//Note//__: Do not change the value unnecessarily. 
- 
-  * **The delay in seconds** is specified manually by the user. Implies a delay in loading data from the database. 
- 
-__//By default//__: receiver type – Netflow, delay – 0 sec; 
-receiver type – Clickstream, delay - 400 sec.\\ 
-__//Note//__: Do not change the value unnecessarily. 
- 
-  * **Exporting** data to other servers. The server address is entered manually by the user. 
- 
-  * **The port type** is selected from the drop-down list. 
- 
-  * **Rotation in seconds** is specified manually by the user. Implies the period of the receiver dump or the period of data loading into the database. 
- 
-__//Note//__: If this option is enabled, the rotation in minutes option is automatically disabled. 
- 
-  * **The queue size** is specified manually by the user. Implies the size of the receiver dump download queue.\\ 
-__//Default value//__: 10.\\ 
-__//Note//__: Do not change the value unnecessarily. 
- 
-  * **The DPI ID** specifies the DPI number. If the value "-1" is specified or not specified, then the DPI number is determined by the recipient's order in the list.\\ 
-__//Note//__: Do not change the value unnecessarily. 
- 
-  * **The port** is a unique parameter and is entered manually by the user.\\ 
-__//By default//__: receiver type – Netflow, port – 1500; 
-receiver type – Clickstream, port - 1501. 
- 
-  * **Rotation by the number of entries in the flow**. It works simultaneously with the rotation parameter in minutes or seconds. 
- 
-  * **The number of dump insertion processes**. Without having to change the value. 
- 
-To change the saved receiver, click on the "Change" button located to the left of each receiver.\\ 
-To remove the receiver, click on the "Delete" button located to the right of each receiver. 
- 
-{{ en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration:change_3.png? 500 }} 
- 
-==== 2 Filtering ==== 
- 
-All parameters are specified by selecting from the output list.\\ 
-To explain the selection, you can click on the auxiliary button located to the right of each parameter. 
- 
-{{ en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration:inf_4.png? 500 }} 
- 
-{{ en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration:inf_5.png? 300 }} 
- 
-==== 3 General ==== 
- 
-Parameters are specified by selecting from the output list, URLs are entered manually by the user.\\ 
-To explain the selection, you can click on the auxiliary button located to the right of each parameter. 
- 
-{{ en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration:url_6.png? 500 }} 
- 
-==== 4 URL Settings ==== 
-All parameters are specified by selecting from the drop-down list. To explain the selection, you can click on the auxiliary button located to the right of each parameter. 
- 
-==== 5 FULLFLOW Log Settings ==== 
-All parameters are specified by selecting from the output list. To explain the selection, you can click on the auxiliary button located to the right of each parameter. 
- 
-==== 6 CLICKSTREAM Log Settings ==== 
-All parameters are specified by selecting from the drop-down list. To explain the selection, you can click on the auxiliary button located to the right of each parameter. 
- 
-==== 7 NAT Log Settings ==== 
-All parameters are specified by selecting from the output list. To explain the selection, you can click on the auxiliary button located to the right of each parameter. 
- 
-==== 8 ONLINEFLOW Log Settings ==== 
-All parameters are specified by selecting from the output list. To explain the selection, you can click on the auxiliary button located to the right of each parameter. 
- 
-==== 9 OpenCellID settings ==== 
- 
-To enable autoload of OpenCellID catalog, select **“Enabled”**. 
- 
-{{ :en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:conf_qoestor_opencellid_en_1.png?600 |}} 
- 
- * **CELL_TOWER_LOADER_API_TOKEN** - token in LocalAPI platform. __[[en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration#token_opencellid|Get a token in the service LocationAPI.]]__ 
- 
-{{ :en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:conf_qoestor_opencellid_en_2.png?600 |}} 
- 
- * **CELL_TOWER_LOG** - level of log. 
- 
-{{ :en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:conf_qoestor_opencellid_en_3.png?600 |}} 
- 
- * **CELL_TOWER_RESPONSE_HOUR** - time interval to update empty data cell towers for report of geo position, hours. 
- 
-{{ :en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:conf_qoestor_opencellid_en_4.png?600 |}} 
- 
-===== Token OpenCellID ===== 
- 
- * Sign up __[[https://my.unwiredlabs.com/|LocationAPI]]__ 
- 
-{{ :dpi:dpi_components:dpiui:user_guide:admin_section:qoestor_man:configuration_qoe_stor:conf_qoestor_opencellid_gettoken_1.png?600 |}} 
- 
- 
- * Move to **API Acess Tokens**, click **Show Token**, copy token. 
- 
-{{ :dpi:dpi_components:dpiui:user_guide:admin_section:qoestor_man:configuration_qoe_stor:conf_qoestor_opencellid_gettoken_2.png?600 |}} 
- 
-===== Save settings =====  
- 
- 
-To save the settings in the configuration, click on the **"Save"** button located on the left in the toolbar.\\ 
-To restart the configuration, click on the **"Restart"** button located in the toolbar.\\ 
-To update the settings, click on the **"Update"** button located in the toolbar. 
- 
-{{ en:dpi:dpi_components:dpiui:user_guide:admin_section:equipment_management:configuration:set_7.png? 600 }}