Appliance installation instruction [Документация VAS Experts]

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:dpi:dpi_brief:install_point_ssg:micra_install [2023/08/30 12:02] elena.krasnobryzhen:dpi:dpi_brief:install_point_ssg:micra_install [2025/05/23 14:02] (current) – ↷ Page moved from en:dpi:dpi_brief:network_preparation:install_point_ssg:micra_install to en:dpi:dpi_brief:install_point_ssg:micra_install elena.krasnobryzh
Line 1: Line 1:
-====== micra_install ======+====== Appliance installation instruction ====== 
 +{{indexmenu_n>2}} 
 + 
 +A typical connection diagram for **x86 server hardware**: 
 + 
 +{{ dpi:dpi_brief:install_point_ssg:equipment_scheme.png?nolink&1200 |}} 
 + 
 +Cards with [[en:dpi:dpi_brief:dpi_requirements#minimum_requirements|10/25/40/100 network ports]] are placed in **slots 1-10**\\ 
 +Each slot has a unique PCIe bus identifier, e.g. **02:00**.\\ 
 +Each port has a unique identifier on the card, e.g: **02:00.0, 02:00.1, 02:00.2, 02:00.3**.\\ 
 + 
 +**Example of interfaces orientation in pairs:** 
 +<code> 
 +   # In, to the subscriber side - port 02:00.0, 02:00.2 
 +in_dev=02:00.0:02:00.2 
 +   # Out, to the Internet side - port 02:00.1, 02:00.3 
 +out_dev=02:00.1:02:00.3 
 +</code> 
 + 
 +Port configuration is described in the section [[en:dpi:dpi_components:platform:dpi_config|DPDK Interfaces Configuration]]. 
 + 
 +Ports **mg0, mg1** are used for SSH management, IPFIX sending (Full flow, NAT log, ClickStream), integration with Radius/PCRF . For fault tolerance, they are combined in LAG. 
 + 
 +The **bmc** port is used to connect to the BMC server controller. 
 + 
 +Each server has two power supplies **psu1, psu2** for power redundancy.